RM Analyzer Help

Action > FibLc

Fiber stress check for a certain load case.

SettingDescription
Action Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function.
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Input-1 > Load case name Load case name where the relevant internal force state is stored.
Input-2 > Stress limit no. Relevant stress limit pair for comparison with the actual stresses due to the current internal force state. Stress limit pairs are numbered objects in the material dataset. They can be arbitrarily defined by the user. Note that the inbuilt default database does normally not contain pre-defined stress limit pairs.
Output-1 > List File Name of list file, where the results of fiber stress check will be written.

Default (Input *): fib<LCname>.lst. No list file will be created if the input field is empty.

Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)

Performing the fiber stress check can be switched off in the Elements > Checks menu for elements which should be excluded.